CVE-2024-32317 1 Tenda 2 Ac10, Ac10 Firmware 2025-03-17 N/A 7.5 HIGH
Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
CVE-2024-25373 1 Tenda 2 Ac10, Ac10 Firmware 2025-03-17 N/A 4.6 MEDIUM
Tenda AC10V4.0 V16.03.10.20 was discovered to contain a stack overflow via the page parameter in the sub_49B384 function.
CVE-2023-27016 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 N/A 9.8 CRITICAL
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27015 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 N/A 9.8 CRITICAL
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_4A75C0 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27014 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 N/A 9.8 CRITICAL
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_46AC38 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27013 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 N/A 9.8 CRITICAL
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the get_parentControl_list_Info function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27012 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 N/A 9.8 CRITICAL
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27019 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 N/A 9.8 CRITICAL
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_458FBC function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27021 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 N/A 9.8 CRITICAL
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27020 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 N/A 9.8 CRITICAL
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27018 1 Tenda 2 Ac10, Ac10 Firmware 2025-02-12 N/A 9.8 CRITICAL
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45EC1C function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2024-2581 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-22 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.
CVE-2023-34568 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-06 N/A 6.7 MEDIUM
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
CVE-2023-34566 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-06 N/A 9.8 CRITICAL
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo.
CVE-2023-34571 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-06 N/A 6.7 MEDIUM
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet.
CVE-2023-34570 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-06 N/A 6.7 MEDIUM
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName.
CVE-2023-34569 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-06 N/A 6.7 MEDIUM
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.
CVE-2023-34567 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-06 N/A 6.7 MEDIUM
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
CVE-2024-2856 1 Tenda 2 Ac10, Ac10 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-45484 1 Tenda 2 Ac10, Ac10 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic.