Total
66 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-34567 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | N/A | 6.7 MEDIUM |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg. | |||||
CVE-2024-2856 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2023-45484 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic. | |||||
CVE-2023-45483 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time. | |||||
CVE-2023-45482 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info. | |||||
CVE-2023-45481 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg. | |||||
CVE-2023-45480 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the src parameter in the function sub_47D878. | |||||
CVE-2023-45479 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098. | |||||
CVE-2023-42320 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01 allows a remote attacker to cause a denial of service via the mac parameter in the GetParentControlInfo function. | |||||
CVE-2023-38937 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. | |||||
CVE-2023-38936 | 1 Tenda | 18 Ac10, Ac10 Firmware, Ac1206 and 15 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | |||||
CVE-2023-38935 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac1206 and 7 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. | |||||
CVE-2023-38933 | 1 Tenda | 18 Ac10, Ac10 Firmware, Ac1206 and 15 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. | |||||
CVE-2023-38931 | 1 Tenda | 16 Ac10, Ac10 Firmware, Ac1206 and 13 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. | |||||
CVE-2023-37717 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient. | |||||
CVE-2023-37716 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting. | |||||
CVE-2023-37711 | 1 Tenda | 4 Ac10, Ac10 Firmware, Ac1206 and 1 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function. | |||||
CVE-2023-37710 | 1 Tenda | 4 Ac10, Ac10 Firmware, Ac1206 and 1 more | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function. | |||||
CVE-2023-37144 | 2 Tenda, Tendacn | 2 Ac10, Ac10 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac. | |||||
CVE-2023-27017 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45DC58 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. |