Total
73 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-32317 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-03-17 | N/A | 7.5 HIGH |
Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function. | |||||
CVE-2024-25373 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-03-17 | N/A | 4.6 MEDIUM |
Tenda AC10V4.0 V16.03.10.20 was discovered to contain a stack overflow via the page parameter in the sub_49B384 function. | |||||
CVE-2023-27016 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | N/A | 9.8 CRITICAL |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | |||||
CVE-2023-27015 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | N/A | 9.8 CRITICAL |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_4A75C0 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | |||||
CVE-2023-27014 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | N/A | 9.8 CRITICAL |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_46AC38 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | |||||
CVE-2023-27013 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | N/A | 9.8 CRITICAL |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the get_parentControl_list_Info function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | |||||
CVE-2023-27012 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | N/A | 9.8 CRITICAL |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | |||||
CVE-2023-27019 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | N/A | 9.8 CRITICAL |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_458FBC function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | |||||
CVE-2023-27021 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | N/A | 9.8 CRITICAL |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | |||||
CVE-2023-27020 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | N/A | 9.8 CRITICAL |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | |||||
CVE-2023-27018 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | N/A | 9.8 CRITICAL |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45EC1C function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | |||||
CVE-2024-2581 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-22 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability. | |||||
CVE-2023-34568 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | N/A | 6.7 MEDIUM |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet. | |||||
CVE-2023-34566 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | N/A | 9.8 CRITICAL |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo. | |||||
CVE-2023-34571 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | N/A | 6.7 MEDIUM |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet. | |||||
CVE-2023-34570 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | N/A | 6.7 MEDIUM |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName. | |||||
CVE-2023-34569 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | N/A | 6.7 MEDIUM |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList. | |||||
CVE-2023-34567 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | N/A | 6.7 MEDIUM |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg. | |||||
CVE-2024-2856 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2023-45484 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic. |