CVE-2018-8858 1 Vecna 2 Vgo, Vgo Firmware 2024-11-21 5.0 MEDIUM 9.8 CRITICAL
If an attacker has access to the firmware from the VGo Robot (Versions 3.0.3.52164 and 3.0.3.53662. Prior versions may also be affected) they may be able to extract credentials.
CVE-2018-8857 1 Philips 8 Brilliance Ct Big Bore, Brilliance Ct Big Bore Firmware, Brilliance 64 and 5 more 2024-11-21 7.2 HIGH 7.8 HIGH
Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) contains fixed credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. An attacker could compromise these credentials and gain access to the system.
CVE-2018-8856 1 Philips 1 E-alert Firmware 2024-11-21 5.0 MEDIUM 9.8 CRITICAL
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.
CVE-2018-8855 1 Echelon 8 I.lon 100, I.lon 100 Firmware, I.lon 600 and 5 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices allow unencrypted Web connections by default, and devices can receive configuration and firmware updates by unsecure FTP.
CVE-2018-8854 1 Philips 1 E-alert Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not properly restrict the size or amount of resources requested or influenced by an actor, which can be used to consume more resources than intended.
CVE-2018-8853 1 Philips 8 Brilliance Ct Big Bore, Brilliance Ct Big Bore Firmware, Brilliance 64 and 5 more 2024-11-21 7.2 HIGH 8.8 HIGH
Philips Brilliance CT devices operate user functions from within a contained kiosk in a Microsoft Windows operating system. Windows boots by default with elevated Windows privileges, enabling a kiosk application, user, or an attacker to potentially attain unauthorized elevated privileges in Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior. Also, attackers may gain access to unauthorized resources from the underlying Windows operating system.
CVE-2018-8852 1 Philips 1 E-alert Firmware 2024-11-21 6.8 MEDIUM 8.8 HIGH
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier.
CVE-2018-8851 1 Echelon 8 I.lon 100, I.lon 100 Firmware, I.lon 600 and 5 more 2024-11-21 5.0 MEDIUM 9.8 CRITICAL
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices store passwords in plaintext, which may allow an attacker with access to the configuration file to log into the SmartServer web user interface.
CVE-2018-8850 1 Philips 1 E-alert Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result in altered control flow, arbitrary control of a resource, or arbitrary code execution.
CVE-2018-8848 1 Philips 1 E-alert Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.
CVE-2018-8847 1 Eaton 2 9000x, 9000x Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
Eaton 9000X DriveA versions 2.0.29 and prior has a stack-based buffer overflow vulnerability, which may allow remote code execution.
CVE-2018-8846 1 Philips 1 E-alert Firmware 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users.
CVE-2018-8845 1 Advantech 4 Webaccess, Webaccess\/nms, Webaccess Dashboard and 1 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a heap-based buffer overflow vulnerability has been identified, which may allow an attacker to execute arbitrary code.
CVE-2018-8844 1 Philips 1 E-alert Firmware 2024-11-21 6.8 MEDIUM 8.8 HIGH
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
CVE-2018-8843 1 Rockwellautomation 1 Arena 2024-11-21 4.3 MEDIUM 5.5 MEDIUM
Rockwell Automation Arena versions 15.10.00 and prior contains a use after free vulnerability caused by processing specially crafted Arena Simulation Software files that may cause the software application to crash, potentially losing any unsaved data..
CVE-2018-8842 1 Philips 1 E-alert Firmware 2024-11-21 3.3 LOW 8.8 HIGH
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet.
CVE-2018-8841 1 Advantech 4 Webaccess, Webaccess\/nms, Webaccess Dashboard and 1 more 2024-11-21 4.6 MEDIUM 7.8 HIGH
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an improper privilege management vulnerability may allow an authenticated user to modify files when read access should only be given to the user.
CVE-2018-8840 2 Indusoft, Industrial-software 2 Web Studio, Intouch Machine Edition 2017 2024-11-21 10.0 HIGH 9.8 CRITICAL
A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.
CVE-2018-8839 1 Deltaww 1 Pmsoft 2024-11-21 4.6 MEDIUM 7.8 HIGH
Delta PMSoft versions 2.10 and prior have multiple stack-based buffer overflow vulnerabilities where a .ppm file can introduce a value larger than is readable by PMSoft's fixed-length stack buffer. This can cause the buffer to be overwritten, which may allow arbitrary code execution or cause the application to crash. CVSS v3 base score: 7.1; CVSS vector string: AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H. Delta Electronics recommends affected users update to at least PMSoft v2.11, which was made available as of March 22, 2018, or the latest available version.
CVE-2018-8838 1 Yokogawa 5 B\/m9000 Cs, B\/m9000 Vp, Centum Cs 3000 and 2 more 2024-11-21 4.4 MEDIUM 6.5 MEDIUM
A weakness in access controls in CENTUM CS 1000 all versions, CENTUM CS 3000 versions R3.09.50 and earlier, CENTUM CS 3000 Small versions R3.09.50 and earlier, CENTUM VP versions R6.03.10 and earlier, CENTUM VP Small versions R6.03.10 and earlier, CENTUM VP Basic versions R6.03.10 and earlier, Exaopc versions R3.75.00 and earlier, B/M9000 CS all versions, and B/M9000 VP versions R8.01.01 and earlier may allow a local attacker to exploit the message management function of the system. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H).