Total
766 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-24939 | 1 Jetbrains | 1 Rider | 2024-11-21 | N/A | 3.3 LOW |
In JetBrains Rider before 2023.3.3 logging of environment variables containing secret values was possible | |||||
CVE-2024-23840 | 1 Goreleaser | 1 Goreleaser | 2024-11-21 | N/A | 5.5 MEDIUM |
GoReleaser builds Go binaries for several platforms, creates a GitHub release and then pushes a Homebrew formula to a tap repository. `goreleaser release --debug` log shows secret values used in the in the custom publisher. This vulnerability is fixed in 1.24.0. | |||||
CVE-2024-23760 | 1 Gambio | 1 Gambio | 2024-11-21 | N/A | 2.7 LOW |
Cleartext Storage of Sensitive Information in Gambio 4.9.2.0 allows attackers to obtain sensitive information via error-handler.log.json and legacy-error-handler.log.txt under the webroot. | |||||
CVE-2024-23758 | 2024-11-21 | N/A | 7.5 HIGH | ||
An issue discovered in Unisys Stealth 5.3.062.0 allows attackers to view sensitive information via the Enterprise ManagementInstaller_msi.log file. | |||||
CVE-2024-23686 | 1 Owasp | 1 Dependency-check | 2024-11-21 | N/A | 5.3 MEDIUM |
DependencyCheck for Maven 9.0.0 to 9.0.6, for CLI version 9.0.0 to 9.0.5, and for Ant versions 9.0.0 to 9.0.5, when used in debug mode, allows an attacker to recover the NVD API Key from a log file. | |||||
CVE-2024-23677 | 1 Splunk | 2 Cloud, Splunk | 2024-11-21 | N/A | 4.3 MEDIUM |
In Splunk Enterprise versions below 9.0.8, the Splunk RapidDiag utility discloses server responses from external applications in a log file. | |||||
CVE-2024-23448 | 1 Elastic | 1 Apm Server | 2024-11-21 | N/A | 5.7 MEDIUM |
An issue was discovered whereby APM Server could log at ERROR level, a response from Elasticsearch indicating that indexing the document failed and that response would contain parts of the original document. Depending on the nature of the document that the APM Server attempted to ingest, this could lead to the insertion of sensitive or private information in the APM Server logs. | |||||
CVE-2024-23242 | 2024-11-21 | N/A | 3.3 LOW | ||
A privacy issue was addressed by not logging contents of text fields. This issue is fixed in macOS Sonoma 14.4, iOS 17.4 and iPadOS 17.4. An app may be able to view Mail data. | |||||
CVE-2024-22464 | 1 Dell | 1 Emc Appsync | 2024-11-21 | N/A | 6.2 MEDIUM |
Dell EMC AppSync, versions from 4.2.0.0 to 4.6.0.0 including all Service Pack releases, contain an exposure of sensitive information vulnerability in AppSync server logs. A high privileged remote attacker could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the vulnerable system with privileges of the compromised account. | |||||
CVE-2024-22440 | 2024-11-21 | N/A | 6.8 MEDIUM | ||
A potential security vulnerability has been identified in HPE Compute Scale-up Server 3200 server. This vulnerability could cause disclosure of sensitive information in log files. | |||||
CVE-2024-22352 | 1 Ibm | 1 Infosphere Information Server | 2024-11-21 | N/A | 6.5 MEDIUM |
IBM InfoSphere Information Server 11.7 stores potentially sensitive information in log files that could be read by a local user. IBM X-Force ID: 280361. | |||||
CVE-2024-22339 | 2024-11-21 | N/A | 4.3 MEDIUM | ||
IBM UrbanCode Deploy (UCD) 7.0 through 7.0.5.20, 7.1 through 7.1.2.16, 7.2 through 7.2.3.9, 7.3 through 7.3.2.4 and IBM DevOps Deploy 8.0 through 8.0.0.1 is vulnerable to a sensitive information due to insufficient obfuscation of sensitive values from some log files. IBM X-Force ID: 279979. | |||||
CVE-2024-22337 | 2024-11-21 | N/A | 5.1 MEDIUM | ||
IBM QRadar Suite 1.10.12.0 through 1.10.17.0 and IBM Cloud Pak for Security 1.10.0.0 through 1.10.11.0 stores potentially sensitive information in log files that could be read by a local user. IBM X-Force ID: 279977. | |||||
CVE-2024-22336 | 2024-11-21 | N/A | 5.1 MEDIUM | ||
IBM QRadar Suite 1.10.12.0 through 1.10.17.0 and IBM Cloud Pak for Security 1.10.0.0 through 1.10.11.0 stores potentially sensitive information in log files that could be read by a local user. IBM X-Force ID: 279976. | |||||
CVE-2024-22335 | 2024-11-21 | N/A | 5.1 MEDIUM | ||
IBM QRadar Suite 1.10.12.0 through 1.10.17.0 and IBM Cloud Pak for Security 1.10.0.0 through 1.10.11.0 stores potentially sensitive information in log files that could be read by a local user. IBM X-Force ID: 279975. | |||||
CVE-2024-22276 | 2024-11-21 | N/A | 5.3 MEDIUM | ||
VMware Cloud Director Object Storage Extension contains an Insertion of Sensitive Information vulnerability. A malicious actor with adjacent access to web/proxy server logging may be able to obtain sensitive information from URLs that are logged. | |||||
CVE-2024-22138 | 2024-11-21 | N/A | 5.3 MEDIUM | ||
Insertion of Sensitive Information into Log File vulnerability in Seraphinite Solutions Seraphinite Accelerator.This issue affects Seraphinite Accelerator: from n/a through 2.20.47. | |||||
CVE-2024-21668 | 1 Mrousavy | 1 React-native-mmkv | 2024-11-21 | N/A | 4.4 MEDIUM |
react-native-mmkv is a library that allows easy use of MMKV inside React Native applications. Before version 2.11.0, the react-native-mmkv logged the optional encryption key for the MMKV database into the Android system log. The key can be obtained by anyone with access to the Android Debugging Bridge (ADB) if it is enabled in the phone settings. This bug is not present on iOS devices. By logging the encryption secret to the system logs, attackers can trivially recover the secret by enabling ADB and undermining an app's thread model. This issue has been patched in version 2.11.0. | |||||
CVE-2024-0912 | 1 Johnsoncontrols | 1 Software House C-cure 9000 Siteserver | 2024-11-21 | N/A | 4.2 MEDIUM |
Under certain circumstances the Microsoft® Internet Information Server (IIS) used to host the C•CURE 9000 Web Server will log Microsoft Windows credential details within logs. There is no impact to non-web service interfaces C•CURE 9000 or prior versions | |||||
CVE-2024-0716 | 1 Byzoro | 2 Smart S150, Smart S150 Firmware | 2024-11-21 | 2.1 LOW | 3.1 LOW |
A vulnerability classified as problematic has been found in Byzoro Smart S150 Management Platform V31R02B15. This affects an unknown part of the file /log/download.php of the component Backup File Handler. The manipulation leads to information disclosure. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The identifier VDB-251541 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |