Total
2898 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-38310 | 2025-02-12 | N/A | 8.2 HIGH | ||
Improper access control in some Intel(R) Graphics Driver software installers may allow an authenticated user to potentially enable escalation of privilege via local access. | |||||
CVE-2024-37355 | 2025-02-12 | N/A | 8.8 HIGH | ||
Improper access control in some Intel(R) Graphics software may allow an authenticated user to potentially enable escalation of privilege via local access. | |||||
CVE-2024-30211 | 2025-02-12 | N/A | 6.0 MEDIUM | ||
Improper access control in some Intel(R) ME driver pack installer engines before version 2422.6.2.0 may allow an authenticated user to potentially enable escalation of privilege via local access. | |||||
CVE-2023-29164 | 2025-02-12 | N/A | 7.3 HIGH | ||
Improper access control in BMC Firmware for the Intel(R) Server Board S2600WF, Intel(R) Server Board S2600ST, Intel(R) Server Board S2600BP, before version 02.01.0017 and Intel(R) Server Board M50CYP and Intel(R) Server Board D50TNP before version R01.01.0009 may allow an authenticated user to enable escalation of privilege via local access. | |||||
CVE-2024-23315 | 1 Automationdirect | 12 P1-540, P1-540 Firmware, P1-550 and 9 more | 2025-02-12 | N/A | 7.5 HIGH |
A read-what-where vulnerability exists in the Programming Software Connection IMM 01A1 Memory Read functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted network packet can lead to a disclosure of sensitive information. An attacker can send an unauthenticated packet to trigger this vulnerability. | |||||
CVE-2024-22187 | 1 Automationdirect | 12 P1-540, P1-540 Firmware, P1-550 and 9 more | 2025-02-12 | N/A | 9.1 CRITICAL |
A write-what-where vulnerability exists in the Programming Software Connection Remote Memory Diagnostics functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted network packet can lead to an arbitrary write. An attacker can send an unauthenticated packet to trigger this vulnerability. | |||||
CVE-2024-1701 | 1 Keerti1924 | 1 Php Mysql User Signup Login System | 2025-02-12 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability has been found in keerti1924 PHP-MYSQL-User-Login-System 1.0 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /edit.php. The manipulation leads to improper access controls. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-254389 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-12370 | 1 Thimpress | 1 Wp Hotel Booking | 2025-02-11 | N/A | 5.3 MEDIUM |
The WP Hotel Booking plugin for WordPress is vulnerable to unauthorized modification of data due to a missing capability check when adding rooms in all versions up to, and including, 2.1.5. This makes it possible for unauthenticated attackers to add rooms with custom prices. | |||||
CVE-2025-21359 | 2025-02-11 | N/A | 7.8 HIGH | ||
Windows Kernel Security Feature Bypass Vulnerability | |||||
CVE-2023-24544 | 1 Buffalo | 24 Bs-gs2008, Bs-gs2008 Firmware, Bs-gs2008p and 21 more | 2025-02-11 | N/A | 8.1 HIGH |
Improper access control vulnerability in Buffalo network devices allows a network-adjacent attacker to obtain specific files of the product. As a result, the product settings may be altered. The affected products and versions are as follows: BS-GSL2024 firmware Ver. 1.10-0.03 and earlier, BS-GSL2016P firmware Ver. 1.10-0.03 and earlier, BS-GSL2016 firmware Ver. 1.10-0.03 and earlier, BS-GS2008 firmware Ver. 1.0.10.01 and earlier, BS-GS2016 firmware Ver. 1.0.10.01 and earlier, BS-GS2024 firmware Ver. 1.0.10.01 and earlier, BS-GS2048 firmware Ver. 1.0.10.01 and earlier, BS-GS2008P firmware Ver. 1.0.10.01 and earlier, BS-GS2016P firmware Ver. 1.0.10.01 and earlier, and BS-GS2024P firmware Ver. 1.0.10.01 and earlier | |||||
CVE-2023-0319 | 1 Gitlab | 1 Gitlab | 2025-02-11 | N/A | 5.8 MEDIUM |
An issue has been discovered in GitLab affecting all versions starting from 13.6 before 15.8.5, all versions starting from 15.9 before 15.9.4, all versions starting from 15.10 before 15.10.1, allowing to read environment names supposed to be restricted to project memebers only. | |||||
CVE-2024-57249 | 2025-02-11 | N/A | 6.5 MEDIUM | ||
Incorrect Access Control in the Preview Function of Gleamtech FileVista 9.2.0.0 allows remote attackers to gain unauthorized access via exploiting a vulnerability in access control mechanisms by removing authentication-related HTTP headers, such as the Cookie header, in the request. This bypasses the authentication process and grants attackers access to sensitive image files without proper login credentials. | |||||
CVE-2023-23575 | 1 Contec | 38 Cps-mc341-a1-111, Cps-mc341-a1-111 Firmware, Cps-mc341-adsc1-111 and 35 more | 2025-02-11 | N/A | 4.3 MEDIUM |
Improper access control vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker to bypass access restriction and access Network Maintenance page, which may result in obtaining the network information of the product. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131). | |||||
CVE-2025-24532 | 2025-02-11 | N/A | 4.3 MEDIUM | ||
A vulnerability has been identified in SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices with role `user` is affected by incorrect authorization in SNMPv3 View configuration. This could allow an attacker to change the View Type of SNMPv3 Views. | |||||
CVE-2024-46948 | 1 Northern.tech | 1 Mender | 2025-02-10 | N/A | 4.3 MEDIUM |
Northern.tech Mender before 3.6.5 and 3.7.x before 3.7.5 has Incorrect Access Control. | |||||
CVE-2024-42988 | 2025-02-10 | N/A | 4.3 MEDIUM | ||
Lack of access control in ChallengeSolves (/api/v1/challenges/<challenge id>/solves) of CTFd v2.0.0 - v3.7.2 allows authenticated users to retrieve a list of users who have solved the challenge, regardless of the Account Visibility settings. The issue is fixed in v3.7.3+. | |||||
CVE-2024-21150 | 1 Oracle | 1 Jd Edwards Enterpriseone Tools | 2025-02-10 | N/A | 6.1 MEDIUM |
Vulnerability in the JD Edwards EnterpriseOne Tools product of Oracle JD Edwards (component: Web Runtime SEC). Supported versions that are affected are Prior to 9.2.8.2. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise JD Edwards EnterpriseOne Tools. Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in JD Edwards EnterpriseOne Tools, attacks may significantly impact additional products (scope change). Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of JD Edwards EnterpriseOne Tools accessible data as well as unauthorized read access to a subset of JD Edwards EnterpriseOne Tools accessible data. CVSS 3.1 Base Score 6.1 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N). | |||||
CVE-2019-20462 | 2025-02-10 | N/A | 5.3 MEDIUM | ||
An issue was discovered on Alecto IVM-100 2019-11-12 devices. The device comes with a serial interface at the board level. By attaching to this serial interface and rebooting the device, a large amount of information is disclosed. This includes the view password and the password of the Wi-Fi access point that the device used. | |||||
CVE-2025-0802 | 1 Mayurik | 1 Best Employee Management System | 2025-02-10 | 7.5 HIGH | 7.3 HIGH |
A vulnerability classified as critical was found in SourceCodester Best Employee Management System 1.0. Affected by this vulnerability is an unknown functionality of the file /admin/View_user.php of the component Administrative Endpoint. The manipulation leads to improper access controls. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-21185 | 1 Microsoft | 1 Edge Chromium | 2025-02-07 | N/A | 6.5 MEDIUM |
Microsoft Edge (Chromium-based) Elevation of Privilege Vulnerability |