Vulnerabilities (CVE)

Filtered by CWE-121
Total 1647 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-33182 1 Tendacn 2 Ac18, Ac18 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/addWifiMacFilter.
CVE-2024-31803 2024-11-21 N/A 6.2 MEDIUM
Buffer Overflow vulnerability in emp-ot v.0.2.4 allows a remote attacker to execute arbitrary code via the FerretCOT<T>::read_pre_data128_from_file function.
CVE-2024-31504 1 Embedded-solutions 1 Freemodbus 2024-11-21 N/A 7.5 HIGH
Buffer Overflow vulnerability in SILA Embedded Solutions GmbH freemodbus v.2018-09-12 allows a remtoe attacker to cause a denial of service via the LINUXTCP server component.
CVE-2024-31163 2024-11-21 N/A 7.2 HIGH
ASUS Download Master has a buffer overflow vulnerability. An unauthenticated remote attacker with administrative privileges can exploit this vulnerability to execute arbitrary system commands on the device.
CVE-2024-30621 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan.
CVE-2024-30392 2024-11-21 N/A 7.5 HIGH
A Stack-based Buffer Overflow vulnerability in Flow Processing Daemon (flowd) of Juniper Networks Junos OS allows an unauthenticated, network-based attacker to cause Denial of Service (DoS). On all Junos OS MX Series platforms with SPC3 and MS-MPC/-MIC, when URL filtering is enabled and a specific URL request is received and processed, flowd will crash and restart. Continuous reception of the specific URL request will lead to a sustained Denial of Service (DoS) condition. This issue affects: Junos OS: * all versions before 21.2R3-S6, * from 21.3 before 21.3R3-S5, * from 21.4 before 21.4R3-S5, * from 22.1 before 22.1R3-S3, * from 22.2 before 22.2R3-S1, * from 22.3 before 22.3R2-S2, 22.3R3, * from 22.4 before 22.4R2-S1, 22.4R3.
CVE-2024-30083 1 Microsoft 4 Windows Server 2012, Windows Server 2016, Windows Server 2019 and 1 more 2024-11-21 N/A 7.5 HIGH
Windows Standards-Based Storage Management Service Denial of Service Vulnerability
CVE-2024-2856 1 Tenda 2 Ac10, Ac10 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2855 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257779. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2852 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2850 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2815 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2814 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2813 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2811 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Affected by this issue is the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257666 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2810 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2809 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2808 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257663. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2807 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2806 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.