CVE-2025-9528

A vulnerability was determined in Linksys E1700 1.0.0.4.003. This vulnerability affects the function systemCommand of the file /goform/systemCommand. Executing manipulation of the argument command can lead to os command injection. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_61/61.md Exploit Third Party Advisory
https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_61/61.md#poc Exploit Third Party Advisory
https://vuldb.com/?ctiid.321545 Permissions Required VDB Entry
https://vuldb.com/?id.321545 Third Party Advisory VDB Entry
https://vuldb.com/?submit.634827 Third Party Advisory VDB Entry
https://www.linksys.com/ Product
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:linksys:e1700_firmware:1.0.0.4.003:*:*:*:*:*:*:*
cpe:2.3:h:linksys:e1700:-:*:*:*:*:*:*:*

History

09 Oct 2025, 16:48

Type Values Removed Values Added
References () https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_61/61.md - () https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_61/61.md - Exploit, Third Party Advisory
References () https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_61/61.md#poc - () https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_61/61.md#poc - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.321545 - () https://vuldb.com/?ctiid.321545 - Permissions Required, VDB Entry
References () https://vuldb.com/?id.321545 - () https://vuldb.com/?id.321545 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?submit.634827 - () https://vuldb.com/?submit.634827 - Third Party Advisory, VDB Entry
References () https://www.linksys.com/ - () https://www.linksys.com/ - Product
CPE cpe:2.3:o:linksys:e1700_firmware:1.0.0.4.003:*:*:*:*:*:*:*
cpe:2.3:h:linksys:e1700:-:*:*:*:*:*:*:*
First Time Linksys e1700 Firmware
Linksys
Linksys e1700

29 Aug 2025, 16:24

Type Values Removed Values Added
Summary
  • (es) Se detectó una vulnerabilidad en Linksys E1700 1.0.0.4.003. Esta vulnerabilidad afecta a la función systemCommand del archivo /goform/systemCommand. La manipulación del argumento command puede provocar la inyección de comandos del sistema operativo.El ataque puede ejecutarse en remoto. Se ha hecho público el exploit y puede que sea utilizado. Se contactó al proveedor con antelación sobre esta divulgación, pero no respondió.

27 Aug 2025, 14:15

Type Values Removed Values Added
New CVE

Information

Published : 2025-08-27 14:15

Updated : 2025-10-09 16:48


NVD link : CVE-2025-9528

Mitre link : CVE-2025-9528

CVE.ORG link : CVE-2025-9528


JSON object : View

Products Affected

linksys

  • e1700
  • e1700_firmware
CWE
CWE-77

Improper Neutralization of Special Elements used in a Command ('Command Injection')

CWE-78

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')