CVE-2025-7549

A vulnerability was found in Tenda FH1201 1.2.0.14(408) and classified as critical. This issue affects the function frmL7ProtForm of the file /goform/L7Prot. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\(408\):*:*:*:*:*:*:*
cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*

History

15 Jul 2025, 18:32

Type Values Removed Values Added
First Time Tenda fh1201 Firmware
Tenda
Tenda fh1201
CPE cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*
cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\(408\):*:*:*:*:*:*:*
References () https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md - () https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md - Exploit, Third Party Advisory
References () https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md#poc - () https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md#poc - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.316247 - () https://vuldb.com/?ctiid.316247 - Permissions Required, VDB Entry
References () https://vuldb.com/?id.316247 - () https://vuldb.com/?id.316247 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?submit.614973 - () https://vuldb.com/?submit.614973 - Third Party Advisory, VDB Entry
References () https://www.tenda.com.cn/ - () https://www.tenda.com.cn/ - Product

14 Jul 2025, 14:15

Type Values Removed Values Added
References () https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md - () https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md -
References () https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md#poc - () https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md#poc -
Summary
  • (es) Se encontró una vulnerabilidad en Tenda FH1201 1.2.0.14(408) y se clasificó como crítica. Este problema afecta a la función frmL7ProtForm del archivo /goform/L7Prot. La manipulación de la página de argumentos provoca un desbordamiento del búfer basado en la pila. El ataque puede ejecutarse en remoto. Se ha hecho público el exploit y puede que sea utilizado.

13 Jul 2025, 23:15

Type Values Removed Values Added
New CVE

Information

Published : 2025-07-13 23:15

Updated : 2025-07-15 18:32


NVD link : CVE-2025-7549

Mitre link : CVE-2025-7549

CVE.ORG link : CVE-2025-7549


JSON object : View

Products Affected

tenda

  • fh1201
  • fh1201_firmware
CWE
CWE-119

Improper Restriction of Operations within the Bounds of a Memory Buffer

CWE-121

Stack-based Buffer Overflow