Show plain JSON{"id": "CVE-2025-5176", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Secondary", "source": "cna@vuldb.com", "cvssData": {"version": "2.0", "baseScore": 7.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Secondary", "source": "cna@vuldb.com", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.3, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "integrityImpact": "LOW", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "LOW", "privilegesRequired": "NONE", "confidentialityImpact": "LOW"}, "impactScore": 3.4, "exploitabilityScore": 3.9}, {"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 9.1, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.2, "exploitabilityScore": 3.9}], "cvssMetricV40": [{"type": "Secondary", "source": "cna@vuldb.com", "cvssData": {"Safety": "NOT_DEFINED", "version": "4.0", "Recovery": "NOT_DEFINED", "baseScore": 6.9, "Automatable": "NOT_DEFINED", "attackVector": "NETWORK", "baseSeverity": "MEDIUM", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "exploitMaturity": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "userInteraction": "NONE", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "NONE", "subIntegrityImpact": "NONE", "vulnIntegrityImpact": "LOW", "integrityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "vulnAvailabilityImpact": "LOW", "availabilityRequirement": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "subConfidentialityImpact": "NONE", "vulnConfidentialityImpact": "LOW", "confidentialityRequirement": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED"}}]}, "published": "2025-05-26T08:15:19.700", "references": [{"url": "https://vuldb.com/?ctiid.310264", "tags": ["Permissions Required", "VDB Entry"], "source": "cna@vuldb.com"}, {"url": "https://vuldb.com/?id.310264", "tags": ["Third Party Advisory", "VDB Entry"], "source": "cna@vuldb.com"}, {"url": "https://vuldb.com/?submit.579849", "tags": ["Third Party Advisory", "VDB Entry"], "source": "cna@vuldb.com"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "cna@vuldb.com", "description": [{"lang": "en", "value": "CWE-74"}, {"lang": "en", "value": "CWE-89"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-89"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability was found in Realce Tecnologia Queue Ticket Kiosk up to 20250517. It has been declared as critical. This vulnerability affects unknown code of the file /adm/index.php of the component Admin Login Page. The manipulation of the argument Usu\u00e1rio leads to sql injection. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way."}, {"lang": "es", "value": "Se detect\u00f3 una vulnerabilidad en Realce Tecnologia Queue Ticket Kiosk hasta la versi\u00f3n 20250517. Se ha declarado cr\u00edtica. Esta vulnerabilidad afecta al c\u00f3digo desconocido del archivo /adm/index.php del componente Admin Login Page. La manipulaci\u00f3n del argumento \"Usu\u00e1rio\" provoca una inyecci\u00f3n SQL. El ataque puede ejecutarse en remoto. Se contact\u00f3 al proveedor con antelaci\u00f3n para informarle sobre esta vulnerabilidad, pero no respondi\u00f3."}], "lastModified": "2025-06-03T15:44:04.310", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:realcetecnologia:queue_ticket_kiosk:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "DE860EEE-3232-4B20-BC66-A7D409D163C8", "versionEndIncluding": "2025-05-17"}], "operator": "OR"}]}], "sourceIdentifier": "cna@vuldb.com"}