A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258147. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Link | Resource |
---|---|
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formSetCfm.md | Exploit Third Party Advisory |
https://vuldb.com/?ctiid.258147 | Permissions Required Third Party Advisory VDB Entry |
https://vuldb.com/?id.258147 | Third Party Advisory VDB Entry |
https://vuldb.com/?submit.301029 | Third Party Advisory VDB Entry |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formSetCfm.md | Exploit Third Party Advisory |
https://vuldb.com/?ctiid.258147 | Permissions Required Third Party Advisory VDB Entry |
https://vuldb.com/?id.258147 | Third Party Advisory VDB Entry |
https://vuldb.com/?submit.301029 | Third Party Advisory VDB Entry |
Configurations
Configuration 1 (hide)
AND |
|
History
15 Jan 2025, 18:20
Type | Values Removed | Values Added |
---|---|---|
CPE | cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:* cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:* |
|
CWE | CWE-787 | |
First Time |
Tenda
Tenda f1203 Firmware Tenda f1203 |
|
References | () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formSetCfm.md - Exploit, Third Party Advisory | |
References | () https://vuldb.com/?ctiid.258147 - Permissions Required, Third Party Advisory, VDB Entry | |
References | () https://vuldb.com/?id.258147 - Third Party Advisory, VDB Entry | |
References | () https://vuldb.com/?submit.301029 - Third Party Advisory, VDB Entry |
21 Nov 2024, 09:10
Type | Values Removed | Values Added |
---|---|---|
References | () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formSetCfm.md - | |
References | () https://vuldb.com/?ctiid.258147 - | |
References | () https://vuldb.com/?id.258147 - | |
References | () https://vuldb.com/?submit.301029 - |
11 Apr 2024, 01:25
Type | Values Removed | Values Added |
---|---|---|
Summary |
|
27 Mar 2024, 14:15
Type | Values Removed | Values Added |
---|---|---|
New CVE |
Information
Published : 2024-03-27 14:15
Updated : 2025-01-15 18:20
NVD link : CVE-2024-2978
Mitre link : CVE-2024-2978
CVE.ORG link : CVE-2024-2978
JSON object : View
Products Affected
tenda
- f1203_firmware
- f1203