CVE-2024-2894

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.257937 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.257937 Third Party Advisory VDB Entry
https://vuldb.com/?submit.300357 Third Party Advisory VDB Entry
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.257937 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.257937 Third Party Advisory VDB Entry
https://vuldb.com/?submit.300357 Third Party Advisory VDB Entry
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*

History

22 Jan 2025, 17:57

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.257937 - () https://vuldb.com/?ctiid.257937 - Permissions Required, Third Party Advisory, VDB Entry
References () https://vuldb.com/?id.257937 - () https://vuldb.com/?id.257937 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?submit.300357 - () https://vuldb.com/?submit.300357 - Third Party Advisory, VDB Entry
CPE cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*
First Time Tenda
Tenda ac7
Tenda ac7 Firmware
CWE CWE-787

21 Nov 2024, 09:10

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md -
References () https://vuldb.com/?ctiid.257937 - () https://vuldb.com/?ctiid.257937 -
References () https://vuldb.com/?id.257937 - () https://vuldb.com/?id.257937 -
References () https://vuldb.com/?submit.300357 - () https://vuldb.com/?submit.300357 -

27 Mar 2024, 12:29

Type Values Removed Values Added
Summary
  • (es) Se encontró una vulnerabilidad en Tenda AC7 15.03.06.44. Ha sido clasificada como crítica. Esto afecta a la función formSetQosBand del archivo /goform/SetNetControlList. La manipulación de la lista de argumentos provoca un desbordamiento de búfer en la región stack de la memoria. Es posible iniciar el ataque de forma remota. El exploit ha sido divulgado al público y puede utilizarse. A esta vulnerabilidad se le asignó el identificador VDB-257937. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera.

26 Mar 2024, 17:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-03-26 17:15

Updated : 2025-01-22 17:57


NVD link : CVE-2024-2894

Mitre link : CVE-2024-2894

CVE.ORG link : CVE-2024-2894


JSON object : View

Products Affected

tenda

  • ac7_firmware
  • ac7
CWE
CWE-121

Stack-based Buffer Overflow

CWE-787

Out-of-bounds Write