CVE-2024-2485

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/SetSpeedWan.md Exploit Third Party Advisory
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/setUsbUnload.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.256892 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.256892 Third Party Advisory VDB Entry
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/SetSpeedWan.md Exploit Third Party Advisory
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/setUsbUnload.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.256892 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.256892 Third Party Advisory VDB Entry
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*
cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*

History

14 Jan 2025, 15:04

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/SetSpeedWan.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/SetSpeedWan.md - Exploit, Third Party Advisory
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/setUsbUnload.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/setUsbUnload.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.256892 - () https://vuldb.com/?ctiid.256892 - Permissions Required, Third Party Advisory, VDB Entry
References () https://vuldb.com/?id.256892 - () https://vuldb.com/?id.256892 - Third Party Advisory, VDB Entry
CWE CWE-787
CPE cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*
cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*
First Time Tenda ac18 Firmware
Tenda
Tenda ac18

21 Nov 2024, 09:09

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/SetSpeedWan.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/SetSpeedWan.md -
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/setUsbUnload.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/setUsbUnload.md -
References () https://vuldb.com/?ctiid.256892 - () https://vuldb.com/?ctiid.256892 -
References () https://vuldb.com/?id.256892 - () https://vuldb.com/?id.256892 -

26 Mar 2024, 20:15

Type Values Removed Values Added
References
  • () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/setUsbUnload.md -

21 Mar 2024, 02:52

Type Values Removed Values Added
Summary
  • (es) Una vulnerabilidad fue encontrada en Tenda AC18 15.03.05.05 y clasificada como crítica. La función formSetSpeedWan del archivo /goform/SetSpeedWan es afectada por esta vulnerabilidad. La manipulación del argumento speed_dir provoca un desbordamiento de búfer en la región stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador de esta vulnerabilidad es VDB-256892. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera.

15 Mar 2024, 07:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-03-15 07:15

Updated : 2025-01-14 15:04


NVD link : CVE-2024-2485

Mitre link : CVE-2024-2485

CVE.ORG link : CVE-2024-2485


JSON object : View

Products Affected

tenda

  • ac18
  • ac18_firmware
CWE
CWE-121

Stack-based Buffer Overflow

CWE-787

Out-of-bounds Write