CVE-2024-10966

A vulnerability, which was classified as critical, has been found in TOTOLINK X18 9.1.0cu.2024_B20220329. Affected by this issue is some unknown functionality of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument enable leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
References
Link Resource
https://github.com/Dreamy-elfland/240914 Exploit
https://vuldb.com/?ctiid.283412 Permissions Required VDB Entry
https://vuldb.com/?id.283412 Third Party Advisory VDB Entry
https://vuldb.com/?submit.437310 Third Party Advisory VDB Entry
https://www.totolink.net/ Product
https://www.youtube.com/watch?v=zRNv1OvT55c Exploit
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:totolink:x18_firmware:9.1.0cu.2024_b20220329:*:*:*:*:*:*:*
cpe:2.3:h:totolink:x18:-:*:*:*:*:*:*:*

History

16 Dec 2024, 23:05

Type Values Removed Values Added
CPE cpe:2.3:h:totolink:x18:-:*:*:*:*:*:*:*
cpe:2.3:o:totolink:x18_firmware:9.1.0cu.2024_b20220329:*:*:*:*:*:*:*
First Time Totolink x18 Firmware
Totolink x18
Totolink
References () https://github.com/Dreamy-elfland/240914 - () https://github.com/Dreamy-elfland/240914 - Exploit
References () https://vuldb.com/?ctiid.283412 - () https://vuldb.com/?ctiid.283412 - Permissions Required, VDB Entry
References () https://vuldb.com/?id.283412 - () https://vuldb.com/?id.283412 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?submit.437310 - () https://vuldb.com/?submit.437310 - Third Party Advisory, VDB Entry
References () https://www.totolink.net/ - () https://www.totolink.net/ - Product
References () https://www.youtube.com/watch?v=zRNv1OvT55c - () https://www.youtube.com/watch?v=zRNv1OvT55c - Exploit

08 Nov 2024, 19:01

Type Values Removed Values Added
Summary
  • (es) Se ha encontrado una vulnerabilidad clasificada como crítica en TOTOLINK X18 9.1.0cu.2024_B20220329. Este problema afecta a algunas funciones desconocidas del archivo /cgi-bin/cstecgi.cgi. La manipulación del argumento enable provoca la inyección de comandos del sistema operativo. El ataque puede ejecutarse de forma remota. El exploit se ha hecho público y puede utilizarse.

07 Nov 2024, 18:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-11-07 18:15

Updated : 2024-12-16 23:05


NVD link : CVE-2024-10966

Mitre link : CVE-2024-10966

CVE.ORG link : CVE-2024-10966


JSON object : View

Products Affected

totolink

  • x18_firmware
  • x18
CWE
CWE-77

Improper Neutralization of Special Elements used in a Command ('Command Injection')

CWE-78

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')