A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.197), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T file. This could allow an attacker to execute code in the context of the current process.
                
            References
                    Configurations
                    Configuration 1 (hide)
| 
 | 
History
                    21 Nov 2024, 08:13
| Type | Values Removed | Values Added | 
|---|---|---|
| References | () https://cert-portal.siemens.com/productcert/html/ssa-407785.html - | |
| References | () https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf - Patch, Vendor Advisory | 
11 Jun 2024, 12:15
| Type | Values Removed | Values Added | 
|---|---|---|
| References | 
 | 
21 Jan 2024, 03:00
| Type | Values Removed | Values Added | 
|---|---|---|
| CPE | cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:* | |
| Summary | A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.197), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T file. This could allow an attacker to execute code in the context of the current process. | 
11 Aug 2023, 20:44
| Type | Values Removed | Values Added | 
|---|---|---|
| CVSS | v2 : v3 : | v2 : unknown v3 : 7.8 | 
| CWE | CWE-787 | |
| CPE | cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:* cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:* cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* | |
| References | (MISC) https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf - Patch, Vendor Advisory | 
08 Aug 2023, 10:15
| Type | Values Removed | Values Added | 
|---|---|---|
| New CVE | 
Information
                Published : 2023-08-08 10:15
Updated : 2024-11-21 08:13
NVD link : CVE-2023-38528
Mitre link : CVE-2023-38528
CVE.ORG link : CVE-2023-38528
JSON object : View
Products Affected
                siemens
- teamcenter_visualization
- parasolid
CWE
                
                    
                        
                        CWE-787
                        
            Out-of-bounds Write