Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority called ACCsvc through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges.
References
Link | Resource |
---|---|
https://community.acer.com/en/kb/articles/14761 | Mitigation Vendor Advisory |
Configurations
History
16 Mar 2022, 17:42
Type | Values Removed | Values Added |
---|---|---|
References | (MISC) https://community.acer.com/en/kb/articles/14761 - Mitigation, Vendor Advisory | |
CPE | cpe:2.3:a:acer:care_center:*:*:*:*:*:*:*:* | |
CWE | CWE-287 | |
CVSS |
v2 : v3 : |
v2 : 7.2
v3 : 7.8 |
10 Mar 2022, 17:53
Type | Values Removed | Values Added |
---|---|---|
New CVE |
Information
Published : 2022-03-10 17:46
Updated : 2024-02-04 22:29
NVD link : CVE-2022-24285
Mitre link : CVE-2022-24285
CVE.ORG link : CVE-2022-24285
JSON object : View
Products Affected
acer
- care_center
CWE
CWE-287
Improper Authentication