Show plain JSON{"id": "CVE-2022-24063", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 6.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "MEDIUM", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true}], "cvssMetricV30": [{"type": "Secondary", "source": "zdi-disclosures@trendmicro.com", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 7.8, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.8}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.8, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.8}]}, "published": "2022-02-18T20:15:18.487", "references": [{"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-255/", "tags": ["Third Party Advisory", "VDB Entry"], "source": "zdi-disclosures@trendmicro.com"}, {"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-255/", "tags": ["Third Party Advisory", "VDB Entry"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "zdi-disclosures@trendmicro.com", "description": [{"lang": "en", "value": "CWE-119"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-787"}]}], "descriptions": [{"lang": "en", "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Sante DICOM Viewer Pro 13.2.0.21165. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JP2 files. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15105."}, {"lang": "es", "value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Sante DICOM Viewer Pro versi\u00f3n 13.2.0.21165. Es requerida una interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. El fallo espec\u00edfico se presenta en el an\u00e1lisis de los archivos JP2. El problema es debido a que no es comprobado apropiadamente los datos suministrados por el usuario, lo que puede resultar en una condici\u00f3n de corrupci\u00f3n de memoria. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-15105"}], "lastModified": "2024-11-21T06:49:45.353", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:santesoft:dicom_viewer_pro:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CC465674-FC4D-404D-9046-7BA34CD26A6B", "versionEndExcluding": "11.9.2"}], "operator": "OR"}]}], "sourceIdentifier": "zdi-disclosures@trendmicro.com"}