Due to improper sanitization MedData HBYS software suffers from a remote SQL injection vulnerability. An unauthenticated attacker with the web access is able to extract critical information from the system.
References
Link | Resource |
---|---|
https://gist.github.com/Blackh4n/9d8feaf1cfb68f66de17361e85f616d4 | Third Party Advisory |
https://gist.github.com/Blackh4n/9d8feaf1cfb68f66de17361e85f616d4 | Third Party Advisory |
Configurations
History
21 Nov 2024, 06:29
Type | Values Removed | Values Added |
---|---|---|
CVSS |
v2 : v3 : |
v2 : 7.5
v3 : 9.9 |
References | () https://gist.github.com/Blackh4n/9d8feaf1cfb68f66de17361e85f616d4 - Third Party Advisory |
17 Nov 2021, 20:12
Type | Values Removed | Values Added |
---|---|---|
CPE | cpe:2.3:a:meddata:hbys:*:*:*:*:*:*:*:* | |
CVSS |
v2 : v3 : |
v2 : 7.5
v3 : 9.8 |
References | (CONFIRM) https://gist.github.com/Blackh4n/9d8feaf1cfb68f66de17361e85f616d4 - Third Party Advisory | |
CWE | CWE-89 |
16 Nov 2021, 17:19
Type | Values Removed | Values Added |
---|---|---|
New CVE |
Information
Published : 2021-11-16 16:15
Updated : 2024-11-21 06:29
NVD link : CVE-2021-43362
Mitre link : CVE-2021-43362
CVE.ORG link : CVE-2021-43362
JSON object : View
Products Affected
meddata
- hbys
CWE
CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')