CVE-2021-40142

In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer.
Configurations

Configuration 1 (hide)

cpe:2.3:a:opcfoundation:local_discover_server:*:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
OR cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:2022:-:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_process_historian_opc_ua_server:-:*:*:*:*:*:*:*

Configuration 3 (hide)

OR cpe:2.3:a:siemens:simatic_net_pc:14:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_net_pc:15:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_net_pc:17:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*
cpe:2.3:a:siemens:simatic_wincc_unified_scada_runtime:-:*:*:*:*:*:*:*
cpe:2.3:a:siemens:telecontrol_server_basic:3.0:*:*:*:*:*:*:*

History

03 Sep 2022, 03:54

Type Values Removed Values Added
CPE cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*
cpe:2.3:a:siemens:simatic_wincc_unified_scada_runtime:-:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_net_pc:14:-:*:*:*:*:*:*
cpe:2.3:a:siemens:telecontrol_server_basic:3.0:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_process_historian_opc_ua_server:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:2022:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_net_pc:17:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_net_pc:15:-:*:*:*:*:*:*
References (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf - (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf - Patch, Third Party Advisory

10 May 2022, 12:15

Type Values Removed Values Added
References
  • (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf -

01 Sep 2021, 01:15

Type Values Removed Values Added
References (MISC) https://opcfoundation.org/security-bulletins/ - (MISC) https://opcfoundation.org/security-bulletins/ - Vendor Advisory
References (MISC) https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf - (MISC) https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf - Patch, Vendor Advisory
CVSS v2 : unknown
v3 : unknown
v2 : 5.0
v3 : 7.5
CPE cpe:2.3:a:opcfoundation:local_discover_server:*:*:*:*:*:*:*:*
CWE CWE-119

27 Aug 2021, 07:15

Type Values Removed Values Added
New CVE

Information

Published : 2021-08-27 07:15

Updated : 2024-02-04 21:47


NVD link : CVE-2021-40142

Mitre link : CVE-2021-40142

CVE.ORG link : CVE-2021-40142


JSON object : View

Products Affected

siemens

  • simatic_wincc_runtime
  • simatic_wincc
  • simatic_process_historian_opc_ua_server
  • simatic_net_pc
  • simatic_wincc_unified_scada_runtime
  • simatic_process_historian_opc_ua_server_firmware
  • telecontrol_server_basic

opcfoundation

  • local_discover_server
CWE
CWE-119

Improper Restriction of Operations within the Bounds of a Memory Buffer