A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)
References
Link | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | Vendor Advisory |
Configurations
Configuration 1 (hide)
|
Configuration 2 (hide)
AND |
|
Configuration 3 (hide)
AND |
|
Configuration 4 (hide)
AND |
|
Configuration 5 (hide)
AND |
|
Configuration 6 (hide)
AND |
|
Configuration 7 (hide)
AND |
|
Configuration 8 (hide)
AND |
|
Configuration 9 (hide)
AND |
|
Configuration 10 (hide)
AND |
|
Configuration 11 (hide)
AND |
|
Configuration 12 (hide)
AND |
|
Configuration 13 (hide)
AND |
|
Configuration 14 (hide)
AND |
|
Configuration 15 (hide)
AND |
|
Configuration 16 (hide)
AND |
|
Configuration 17 (hide)
AND |
|
Configuration 18 (hide)
AND |
|
Configuration 19 (hide)
AND |
|
Configuration 20 (hide)
AND |
|
History
13 Mar 2023, 15:28
Type | Values Removed | Values Added |
---|---|---|
CPE | cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:* |
cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:p2_ethernet:*:*:* cpe:2.3:o:siemens:desigo_pxc00-u_firmware:*:*:*:*:*:*:*:* cpe:2.3:h:siemens:desigo_pxc00-u:-:*:*:*:*:*:*:* cpe:2.3:o:siemens:desigo_pxm20-e_firmware:*:*:*:*:*:*:*:* cpe:2.3:h:siemens:desigo_pxc64-u:-:*:*:*:*:*:*:* cpe:2.3:o:siemens:desigo_pxc22.1-e.d_firmware:*:*:*:*:*:*:*:* cpe:2.3:h:siemens:desigo_pxc36.1-e.d:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:desigo_pxm20-e:-:*:*:*:*:*:*:* cpe:2.3:o:siemens:desigo_pxc200-e.d_firmware:*:*:*:*:*:*:*:* cpe:2.3:h:siemens:desigo_pxc22.1-e.d:-:*:*:*:*:*:*:* cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:p2_ethernet:*:*:* cpe:2.3:h:siemens:desigo_pxc200-e.d:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:desigo_pxc100-e.d:-:*:*:*:*:*:*:* cpe:2.3:o:siemens:desigo_pxc50-e.d_firmware:*:*:*:*:*:*:*:* cpe:2.3:h:siemens:desigo_pxc00-e.d:-:*:*:*:*:*:*:* cpe:2.3:o:siemens:desigo_pxc12-e.d_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:siemens:desigo_pxc22-e.d_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:siemens:desigo_pxc001-e.d_firmware:*:*:*:*:*:*:*:* cpe:2.3:h:siemens:desigo_pxc12-e.d:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:desigo_pxc128-u:-:*:*:*:*:*:*:* cpe:2.3:o:siemens:desigo_pxc100-e.d_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:siemens:desigo_pxc36.1-e.d_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:bacnet:*:*:* cpe:2.3:h:siemens:desigo_pxc22-e.d:-:*:*:*:*:*:*:* cpe:2.3:o:siemens:desigo_pxc128-u_firmware:*:*:*:*:*:*:*:* cpe:2.3:h:siemens:desigo_pxc001-e.d:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:desigo_pxc50-e.d:-:*:*:*:*:*:*:* cpe:2.3:o:siemens:desigo_pxc64-u_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:siemens:desigo_pxc00-e.d_firmware:*:*:*:*:*:*:*:* cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:bacnet:*:*:* |
20 May 2022, 13:15
Type | Values Removed | Values Added |
---|---|---|
Summary | A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016) |
12 Apr 2022, 09:15
Type | Values Removed | Values Added |
---|---|---|
Summary | A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions), Desigo PXC00-E.D (All versions >= V2.3), Desigo PXC00-U (All versions >= V2.3), Desigo PXC001-E.D (All versions >= V2.3), Desigo PXC100-E.D (All versions >= V2.3), Desigo PXC12-E.D (All versions >= V2.3), Desigo PXC128-U (All versions >= V2.3), Desigo PXC200-E.D (All versions >= V2.3), Desigo PXC22-E.D (All versions >= V2.3), Desigo PXC22.1-E.D (All versions >= V2.3), Desigo PXC36.1-E.D (All versions >= V2.3), Desigo PXC50-E.D (All versions >= V2.3), Desigo PXC64-U (All versions >= V2.3), Desigo PXM20-E (All versions >= V2.3), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016) |
14 Dec 2021, 12:15
Type | Values Removed | Values Added |
---|---|---|
Summary | A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions), APOGEE PXC Compact (P2 Ethernet) (All versions), APOGEE PXC Modular (BACnet) (All versions), APOGEE PXC Modular (P2 Ethernet) (All versions), Desigo PXC00-E.D (All versions >= V2.3), Desigo PXC00-U (All versions >= V2.3), Desigo PXC001-E.D (All versions >= V2.3), Desigo PXC100-E.D (All versions >= V2.3), Desigo PXC12-E.D (All versions >= V2.3), Desigo PXC128-U (All versions >= V2.3), Desigo PXC200-E.D (All versions >= V2.3), Desigo PXC22-E.D (All versions >= V2.3), Desigo PXC22.1-E.D (All versions >= V2.3), Desigo PXC36.1-E.D (All versions >= V2.3), Desigo PXC50-E.D (All versions >= V2.3), Desigo PXC64-U (All versions >= V2.3), Desigo PXM20-E (All versions >= V2.3), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions), TALON TC Modular (BACnet) (All versions). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016) | |
CWE | CWE-170 |
12 Nov 2021, 18:15
Type | Values Removed | Values Added |
---|---|---|
New CVE |
Information
Published : 2021-11-09 12:15
Updated : 2024-02-04 22:08
NVD link : CVE-2021-31887
Mitre link : CVE-2021-31887
CVE.ORG link : CVE-2021-31887
JSON object : View
Products Affected
siemens
- desigo_pxc200-e.d_firmware
- desigo_pxc50-e.d_firmware
- nucleus_source_code
- desigo_pxc100-e.d_firmware
- apogee_modular_building_controller
- talon_tc_compact_firmware
- talon_tc_modular
- apogee_pxc_compact_firmware
- nucleus_net
- desigo_pxc22.1-e.d_firmware
- apogee_pxc_compact
- desigo_pxm20-e
- desigo_pxc00-u_firmware
- desigo_pxc00-e.d
- nucleus_readystart_v3
- talon_tc_modular_firmware
- apogee_modular_equiment_controller
- desigo_pxc100-e.d
- desigo_pxc200-e.d
- desigo_pxc36.1-e.d
- desigo_pxc64-u
- desigo_pxc36.1-e.d_firmware
- desigo_pxm20-e_firmware
- desigo_pxc50-e.d
- desigo_pxc64-u_firmware
- desigo_pxc128-u
- apogee_pxc_modular_firmware
- apogee_modular_equiment_controller_firmware
- desigo_pxc00-e.d_firmware
- desigo_pxc22-e.d_firmware
- desigo_pxc001-e.d_firmware
- desigo_pxc22-e.d
- desigo_pxc12-e.d
- desigo_pxc001-e.d
- desigo_pxc12-e.d_firmware
- desigo_pxc22.1-e.d
- desigo_pxc00-u
- desigo_pxc128-u_firmware
- apogee_pxc_modular
- apogee_modular_building_controller_firmware
- talon_tc_compact