In BIND 9.8.5 -> 9.8.8, 9.9.3 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.9.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND 9 Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.11 of the BIND 9.17 development branch, when a vulnerable version of named receives a malformed IXFR triggering the flaw described above, the named process will terminate due to a failed assertion the next time the transferred secondary zone is refreshed.
References
Configurations
Configuration 1 (hide)
|
Configuration 2 (hide)
|
Configuration 3 (hide)
|
Configuration 4 (hide)
|
Configuration 5 (hide)
|
Configuration 6 (hide)
AND |
|
Configuration 7 (hide)
AND |
|
Configuration 8 (hide)
AND |
|
Configuration 9 (hide)
AND |
|
Configuration 10 (hide)
AND |
|
Configuration 11 (hide)
AND |
|
Configuration 12 (hide)
AND |
|
Configuration 13 (hide)
AND |
|
Configuration 14 (hide)
AND |
|
History
25 Apr 2022, 20:14
Type | Values Removed | Values Added |
---|---|---|
CPE | cpe:2.3:h:netapp:h300s:-:*:*:*:*:*:*:* cpe:2.3:h:netapp:h700s:-:*:*:*:*:*:*:* cpe:2.3:h:netapp:h410s:-:*:*:*:*:*:*:* cpe:2.3:o:netapp:aff_500f_firmware:-:*:*:*:*:*:*:* cpe:2.3:a:siemens:sinec_infrastructure_network_services:*:*:*:*:*:*:*:* cpe:2.3:h:netapp:h700e:-:*:*:*:*:*:*:* cpe:2.3:o:netapp:h300e_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:netapp:aff_a250_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:netapp:h500e_firmware:-:*:*:*:*:*:*:* cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vsphere:*:* cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:* cpe:2.3:h:netapp:aff_500f:-:*:*:*:*:*:*:* cpe:2.3:h:netapp:h500e:-:*:*:*:*:*:*:* cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:* cpe:2.3:h:netapp:h500s:-:*:*:*:*:*:*:* cpe:2.3:a:netapp:cloud_backup:-:*:*:*:*:*:*:* cpe:2.3:h:netapp:aff_a250:-:*:*:*:*:*:*:* cpe:2.3:h:netapp:h300e:-:*:*:*:*:*:*:* cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:netapp:h700e_firmware:-:*:*:*:*:*:*:* |
|
References | (CONFIRM) https://security.netapp.com/advisory/ntap-20210521-0006/ - Third Party Advisory | |
References | (CONFIRM) https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf - Patch, Third Party Advisory |
10 Mar 2022, 17:41
Type | Values Removed | Values Added |
---|---|---|
References |
|
21 May 2021, 09:15
Type | Values Removed | Values Added |
---|---|---|
References |
|
Information
Published : 2021-04-29 01:15
Updated : 2024-02-04 21:47
NVD link : CVE-2021-25214
Mitre link : CVE-2021-25214
CVE.ORG link : CVE-2021-25214
JSON object : View
Products Affected
netapp
- h500s
- aff_500f_firmware
- h300s
- h300s_firmware
- h700e_firmware
- h700e
- h700s_firmware
- h300e
- h410s_firmware
- h500e_firmware
- h500e
- active_iq_unified_manager
- h700s
- cloud_backup
- h410s
- aff_500f
- aff_a250_firmware
- h300e_firmware
- h500s_firmware
- aff_a250
debian
- debian_linux
fedoraproject
- fedora
isc
- bind
siemens
- sinec_infrastructure_network_services
CWE
CWE-617
Reachable Assertion