CVE-2021-23842

Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\'s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet.
References
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:bosch:amc2_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:bosch:amc2:-:*:*:*:*:*:*:*

Configuration 2 (hide)

cpe:2.3:a:bosch:access_management_system:3.0:*:*:*:*:*:*:*

Configuration 3 (hide)

cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*

Configuration 4 (hide)

cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*

History

28 Jan 2022, 17:58

Type Values Removed Values Added
CVSS v2 : unknown
v3 : unknown
v2 : 3.6
v3 : 7.1
CPE cpe:2.3:o:bosch:amc2_firmware:-:*:*:*:*:*:*:*
cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*
cpe:2.3:a:bosch:access_management_system:3.0:*:*:*:*:*:*:*
cpe:2.3:h:bosch:amc2:-:*:*:*:*:*:*:*
cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*
References (CONFIRM) https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html - (CONFIRM) https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html - Mitigation, Vendor Advisory
CWE CWE-798

19 Jan 2022, 21:15

Type Values Removed Values Added
New CVE

Information

Published : 2022-01-19 21:15

Updated : 2024-02-04 22:08


NVD link : CVE-2021-23842

Mitre link : CVE-2021-23842

CVE.ORG link : CVE-2021-23842


JSON object : View

Products Affected

bosch

  • access_professional_edition
  • amc2_firmware
  • access_management_system
  • amc2
  • building_integration_system
CWE
CWE-798

Use of Hard-coded Credentials

CWE-321

Use of Hard-coded Cryptographic Key