CVE-2021-22276

The vulnerability allows a successful attacker to bypass the integrity check of FW uploaded to the free@home System Access Point.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:abb:system_access_point_2.0_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:abb:system_access_point_2.0:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:abb:system_access_point_127v_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:abb:system_access_point_127v:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:abb:wl-system_access_point_127v_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:abb:wl-system_access_point_127v:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:abb:wl-system_access_point_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:abb:wl-system_access_point:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:abb:wl-system_access_point_2.0_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:abb:wl-system_access_point_2.0:-:*:*:*:*:*:*:*

History

06 Oct 2021, 13:23

Type Values Removed Values Added
References (MISC) https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A6475&LanguageCode=en&DocumentPartId=&Action=Launch - (MISC) https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A6475&LanguageCode=en&DocumentPartId=&Action=Launch - Vendor Advisory
CPE cpe:2.3:o:abb:wl-system_access_point_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:abb:wl-system_access_point_127v:-:*:*:*:*:*:*:*
cpe:2.3:h:abb:system_access_point_2.0:-:*:*:*:*:*:*:*
cpe:2.3:h:abb:wl-system_access_point:-:*:*:*:*:*:*:*
cpe:2.3:o:abb:system_access_point_2.0_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:abb:wl-system_access_point_2.0:-:*:*:*:*:*:*:*
cpe:2.3:o:abb:wl-system_access_point_2.0_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:abb:system_access_point_127v_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:abb:wl-system_access_point_127v_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:abb:system_access_point_127v:-:*:*:*:*:*:*:*
CVSS v2 : unknown
v3 : unknown
v2 : 4.3
v3 : 5.5
CWE CWE-354

23 Sep 2021, 17:15

Type Values Removed Values Added
New CVE

Information

Published : 2021-09-23 17:15

Updated : 2024-02-04 22:08


NVD link : CVE-2021-22276

Mitre link : CVE-2021-22276

CVE.ORG link : CVE-2021-22276


JSON object : View

Products Affected

abb

  • wl-system_access_point
  • wl-system_access_point_firmware
  • wl-system_access_point_2.0
  • system_access_point_127v
  • wl-system_access_point_127v
  • system_access_point_2.0
  • system_access_point_127v_firmware
  • system_access_point_2.0_firmware
  • wl-system_access_point_127v_firmware
  • wl-system_access_point_2.0_firmware
CWE
CWE-354

Improper Validation of Integrity Check Value

CWE-200

Exposure of Sensitive Information to an Unauthorized Actor