A restricted desktop environment escape vulnerability exists in the Kiosk Mode functionality of affected devices. Specially crafted inputs can allow the user to escape the restricted environment, resulting in access to the underlying operating system. Affected devices include the following GE Ultrasound Products: Vivid products - all versions; LOGIQ - all versions not including LOGIQ 100 Pro; Voluson - all versions; Versana Essential - all versions; Invenia ABUS Scan station - all versions; Venue - all versions not including Venue 40 R1-3 and Venue 50 R4-5
References
Link Resource
https://www.us-cert.gov/ics/advisories/icsma-20-049-02 Third Party Advisory US Government Resource
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:ge:vivid_e95_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:vivid_e95:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:ge:vivid_e90_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:vivid_e90:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:ge:vivid_s70n_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:vivid_s70n:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:ge:vivid_t8_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:vivid_t8:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:ge:vivid_t9_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:vivid_t9:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:ge:vivid_iq_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:vivid_iq:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:ge:logiq_e10_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:logiq_e10:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:ge:logiq_e9_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:logiq_e9:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:ge:logiq_s8_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:logiq_s8:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:ge:logiq_s7_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:logiq_s7:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:ge:logiq_p9_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:logiq_p9:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:ge:logiq_e9_with_xdclear_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:logiq_e9_with_xdclear:-:*:*:*:*:*:*:*

Configuration 13 (hide)

AND
cpe:2.3:o:ge:voluson_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:voluson:-:*:*:*:*:*:*:*

Configuration 14 (hide)

AND
cpe:2.3:o:ge:versana_essential_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:versana_essential:-:*:*:*:*:*:*:*

Configuration 15 (hide)

AND
cpe:2.3:o:ge:invenia_abus_scan_station_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:invenia_abus_scan_station:-:*:*:*:*:*:*:*

Configuration 16 (hide)

AND
cpe:2.3:o:ge:venue_go_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:ge:venue_go:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2020-02-20 21:15

Updated : 2024-02-04 20:39


NVD link : CVE-2020-6977

Mitre link : CVE-2020-6977

CVE.ORG link : CVE-2020-6977


JSON object : View

Products Affected

ge

  • logiq_p9
  • logiq_s8
  • logiq_s8_firmware
  • versana_essential_firmware
  • vivid_s70n_firmware
  • vivid_e95_firmware
  • versana_essential
  • logiq_s7_firmware
  • logiq_e9_with_xdclear
  • logiq_p9_firmware
  • vivid_e90
  • logiq_e9_with_xdclear_firmware
  • vivid_e95
  • invenia_abus_scan_station
  • logiq_e10_firmware
  • logiq_e9_firmware
  • logiq_e10
  • vivid_iq_firmware
  • vivid_s70n
  • venue_go
  • vivid_t9_firmware
  • voluson_firmware
  • vivid_iq
  • invenia_abus_scan_station_firmware
  • vivid_t8_firmware
  • venue_go_firmware
  • logiq_s7
  • vivid_t9
  • vivid_t8
  • voluson
  • logiq_e9
  • vivid_e90_firmware
CWE
CWE-20

Improper Input Validation

NVD-CWE-Other CWE-693

Protection Mechanism Failure