A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11885)
References
Link | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf | Vendor Advisory |
https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04 | Third Party Advisory US Government Resource |
https://www.zerodayinitiative.com/advisories/ZDI-21-047/ | Third Party Advisory VDB Entry |
https://www.zerodayinitiative.com/advisories/ZDI-21-054/ | Third Party Advisory VDB Entry |
https://www.zerodayinitiative.com/advisories/ZDI-21-073/ | Third Party Advisory VDB Entry |
Configurations
Configuration 1 (hide)
|
History
12 Oct 2022, 16:45
Type | Values Removed | Values Added |
---|---|---|
CPE | cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:* |
cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack1:*:*:*:*:*:* cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:* cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack5:*:*:*:*:*:* cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack7:*:*:*:*:*:* cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack11:*:*:*:*:*:* cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack8:*:*:*:*:*:* cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:* cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack3:*:*:*:*:*:* cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack9:*:*:*:*:*:* cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack4:*:*:*:*:*:* cpe:2.3:a:siemens:solid_edge:se2020:-:*:*:*:*:*:* cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack10:*:*:*:*:*:* cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack6:*:*:*:*:*:* cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack2:*:*:*:*:*:* |
References | (MISC) https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf - Vendor Advisory |
19 May 2021, 16:15
Type | Values Removed | Values Added |
---|---|---|
References |
|
|
Summary | A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11885) |
Information
Published : 2021-01-12 21:15
Updated : 2024-02-04 21:23
NVD link : CVE-2020-28383
Mitre link : CVE-2020-28383
CVE.ORG link : CVE-2020-28383
JSON object : View
Products Affected
siemens
- jt2go
- solid_edge
- teamcenter_visualization
CWE
CWE-787
Out-of-bounds Write