Show plain JSON{"id": "CVE-2020-28217", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2020-12-11T01:15:11.707", "references": [{"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-03", "tags": ["Third Party Advisory", "US Government Resource"], "source": "cybersecurity@se.com"}, {"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-06/", "tags": ["Vendor Advisory"], "source": "cybersecurity@se.com"}, {"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-03", "tags": ["Third Party Advisory", "US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-06/", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "cybersecurity@se.com", "description": [{"lang": "en", "value": "CWE-311"}]}], "descriptions": [{"lang": "en", "value": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol."}, {"lang": "es", "value": "Una CWE-311: Se presenta una vulnerabilidad de Falta de Cifrado de Datos Confidenciales en Easergy T300 (versiones de firmware 2.7 y anteriores), que podr\u00eda permitir a un atacante leer el tr\u00e1fico de red a trav\u00e9s del protocolo HTTP"}], "lastModified": "2024-11-21T05:22:29.607", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:easergy_t300_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A7763787-4033-4B18-B50E-67B47C6388FA", "versionEndIncluding": "2.7"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:easergy_t300:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "45E6C3FA-001D-449A-A512-327FA0C9AC5A"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cybersecurity@se.com"}