Show plain JSON{"id": "CVE-2020-27278", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 3.6, "accessVector": "LOCAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 4.9, "baseSeverity": "LOW", "obtainAllPrivilege": false, "exploitabilityScore": 3.9, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 5.2, "attackVector": "PHYSICAL", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N", "integrityImpact": "LOW", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 4.2, "exploitabilityScore": 0.9}]}, "published": "2021-03-15T22:15:12.873", "references": [{"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-047-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "ics-cert@hq.dhs.gov"}, {"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-047-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "description": [{"lang": "en", "value": "CWE-798"}]}], "descriptions": [{"lang": "en", "value": "In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, hard-coded credentials in the ventilator allow attackers with physical access to obtain admin privileges for the device\u2019s configuration interface."}, {"lang": "es", "value": "En Hamilton Medical AG, T1-Ventillator versiones 2.2.3 y anteriores, unas credenciales embebidas en el ventilator permiten a atacantes con acceso f\u00edsico alcanzar privilegios de administrador para la interfaz de configuraci\u00f3n del dispositivo"}], "lastModified": "2024-11-21T05:20:59.140", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:hamilton-medical:hamilton-t1_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "425D6578-CE4D-4417-B92C-12C10C837EC2", "versionEndIncluding": "2.2.3"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:hamilton-medical:hamilton-t1:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "3F037FC9-EE0F-4328-9BB1-0628DB4B66FA"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "ics-cert@hq.dhs.gov"}