Show plain JSON{"id": "CVE-2020-16247", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 3.6, "accessVector": "LOCAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 4.9, "baseSeverity": "LOW", "obtainAllPrivilege": false, "exploitabilityScore": 3.9, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.1, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 5.2, "exploitabilityScore": 1.8}]}, "published": "2020-09-18T18:15:17.113", "references": [{"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "ics-cert@hq.dhs.gov"}, {"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "description": [{"lang": "en", "value": "CWE-16"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-668"}]}], "descriptions": [{"lang": "en", "value": "Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource."}, {"lang": "es", "value": "Philips Clinical Collaboration Platform, versiones 12.2.1 y anteriores. El producto expone un recurso a la esfera de control incorrecta, proporcionando a los actores no deseados un acceso inapropiado al recurso"}], "lastModified": "2024-11-21T05:07:01.237", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:philips:clinical_collaboration_platform:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "53A1D5DF-AD61-4A42-8021-C0FFBCB98144", "versionEndIncluding": "12.2.1"}], "operator": "OR"}]}], "sourceIdentifier": "ics-cert@hq.dhs.gov"}