CVE-2020-15791

A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials.
References
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-300_cpu_312_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_312:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_pn_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_pn:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_pn_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_317-2_pn:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_dp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_317-2_dp:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_dp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_315f-2_dp:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_pn_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_315f-2_pn:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-300_cpu_317f-2_pn_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_317f-2_pn:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-300_cpu_317f-2_dp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu_317f-2_dp:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-400_cpu_412_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_412:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-400_cpu_414_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_414:-:*:*:*:*:*:*:*

Configuration 13 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-400_cpu_416_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_416:-:*:*:*:*:*:*:*

Configuration 14 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-400_cpu_417_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_cpu_417:-:*:*:*:*:*:*:*

History

No history.

Information

Published : 2020-09-09 19:15

Updated : 2024-02-04 21:00


NVD link : CVE-2020-15791

Mitre link : CVE-2020-15791

CVE.ORG link : CVE-2020-15791


JSON object : View

Products Affected

siemens

  • simatic_s7-300_cpu_315-2_dp_firmware
  • simatic_s7-300_cpu_315f-2_pn_firmware
  • simatic_s7-400_cpu_417_firmware
  • simatic_s7-300_cpu_317-2_pn
  • simatic_s7-300_cpu_315-2_pn_firmware
  • simatic_s7-400_cpu_412
  • simatic_s7-300_cpu_314_firmware
  • simatic_s7-300_cpu_317f-2_dp
  • simatic_s7-400_cpu_416
  • simatic_s7-300_cpu_315f-2_pn
  • simatic_s7-300_cpu_315-2_dp
  • simatic_s7-300_cpu_317-2_pn_firmware
  • simatic_s7-300_cpu_317f-2_pn
  • simatic_s7-300_cpu_317f-2_pn_firmware
  • simatic_s7-300_cpu_317-2_dp_firmware
  • simatic_s7-400_cpu_414
  • simatic_s7-300_cpu_315f-2_dp
  • simatic_s7-300_cpu_317-2_dp
  • simatic_s7-300_cpu_314
  • simatic_s7-400_cpu_414_firmware
  • simatic_s7-300_cpu_312_firmware
  • simatic_s7-300_cpu_312
  • simatic_s7-400_cpu_416_firmware
  • simatic_s7-400_cpu_412_firmware
  • simatic_s7-300_cpu_317f-2_dp_firmware
  • simatic_s7-300_cpu_315f-2_dp_firmware
  • simatic_s7-400_cpu_417
  • simatic_s7-300_cpu_315-2_pn
CWE
CWE-522