Show plain JSON{"id": "CVE-2019-9863", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 10.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "authentication": "NONE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": false, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2019-03-27T14:29:02.127", "references": [{"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-034.txt", "tags": ["Exploit", "Third Party Advisory"], "source": "cve@mitre.org"}, {"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2018-034.txt", "tags": ["Exploit", "Third Party Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-330"}]}], "descriptions": [{"lang": "en", "value": "Due to the use of an insecure algorithm for rolling codes in the ABUS Secvest wireless alarm system FUAA50000 3.01.01 and its remote controls FUBE50014 and FUBE50015, an attacker is able to predict valid future rolling codes, and can thus remotely control the alarm system in an unauthorized way."}, {"lang": "es", "value": "Debido al uso de un algoritmo inseguro para c\u00f3digos evolutivos en el sistema de alarma inal\u00e1mbrica ABUS Secvest FUAA50000 3.01.01 y sus controles remotos FUBE50014 y FUBE50015, un atacante puede predecir c\u00f3digos evolutivos futuros y, as\u00ed, controlar remotamente el sistema de alarma de forma no autorizada."}], "lastModified": "2024-11-21T04:52:27.797", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:abus:secvest_wireless_alarm_system_fuaa50000_firmware:3.01.01:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "3C5A31E7-5281-4EDC-9CC5-A887857BB6B7"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:abus:secvest_wireless_alarm_system_fuaa50000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "CD534B70-3FA6-4712-A30E-A9BEEB9A91CB"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:abus:secvest_wireless_remote_control_fube50014_firmware:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "36446080-FC7A-40C4-B3FA-E431B7208B54"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:abus:secvest_wireless_remote_control_fube50014:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "FE991250-A833-4D6D-9CAE-8802C81917E5"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:abus:secvest_wireless_remote_control_fube50015_firmware:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9837869E-A954-4E05-B8FA-FF4D41B45E0E"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:abus:secvest_wireless_remote_control_fube50015:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "FF0E3110-7E9E-4FE2-9611-78B4D9819927"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cve@mitre.org"}