Show plain JSON{"id": "CVE-2019-6846", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 4.3, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "MEDIUM", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 6.5, "attackVector": "NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 3.6, "exploitabilityScore": 2.8}]}, "published": "2019-10-29T19:15:22.187", "references": [{"url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02", "tags": ["Vendor Advisory"], "source": "cybersecurity@se.com"}, {"url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "cybersecurity@se.com", "description": [{"lang": "en", "value": "CWE-319"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-319"}]}], "descriptions": [{"lang": "en", "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol."}, {"lang": "es", "value": "Una CWE-319: Existe una vulnerabilidad de Transmisi\u00f3n de Texto Sin Cifrar de Informaci\u00f3n Confidencial en Modicon M580, Modicon M340, Modicon BMxCRA y los m\u00f3dulos 140CRA (todas las versiones de firmware), que podr\u00edan causar una divulgaci\u00f3n de informaci\u00f3n cuando se utiliza el protocolo FTP."}], "lastModified": "2024-11-21T04:47:16.200", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D52D735D-8AB5-40FE-A83F-266977601571"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "E876C738-ABF6-4864-98A6-1E06E96A0DF4"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "05CBA9AD-ECB7-453F-8551-DD176FDE8043"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "138681A2-0146-492B-8E10-06849FC27C6E"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:modicon_bmxcra_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E4E41AAB-05A3-43A4-B97A-34F265E25F40"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:modicon_bmxcra:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F80F2F1C-F681-4498-942E-31EDA9CF79F8"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:modicon_140cra_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "76F5D4B2-1C0A-45E8-993C-DBBA4F745345"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:modicon_140cra:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "94575CFC-1395-4BB4-8D4F-AA41F7068A26"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cybersecurity@se.com"}