Show plain JSON{"id": "CVE-2019-16871", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 9.3, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "authentication": "NONE", "integrityImpact": "COMPLETE", "accessComplexity": "MEDIUM", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": false, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2019-12-19T21:15:13.573", "references": [{"url": "https://download.beckhoff.com/download/document/product-security/Advisories/advisory-2017-001.pdf", "tags": ["Vendor Advisory"], "source": "cve@mitre.org"}, {"url": "https://www.ic4.be/2019/12/18/beckhoff-cve-2019-16871/#more-648", "tags": ["Exploit", "Third Party Advisory"], "source": "cve@mitre.org"}, {"url": "https://download.beckhoff.com/download/document/product-security/Advisories/advisory-2017-001.pdf", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://www.ic4.be/2019/12/18/beckhoff-cve-2019-16871/#more-648", "tags": ["Exploit", "Third Party Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-290"}]}], "descriptions": [{"lang": "en", "value": "Beckhoff Embedded Windows PLCs through 3.1.4024.0, and Beckhoff Twincat on Windows Engineering stations, allow an attacker to achieve Remote Code Execution (as SYSTEM) via the Beckhoff ADS protocol."}, {"lang": "es", "value": "Los PLC Beckhoff Embedded Windows versiones hasta 3.1.4024.0 y Beckhoff Twincat sobre las estaciones de Windows Engineering, permiten a un atacante lograr una ejecuci\u00f3n de c\u00f3digo remota (como SYSTEM) por medio del protocolo ADS de Beckhoff."}], "lastModified": "2024-11-21T04:31:14.783", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:beckhoff:twincat:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "5CE9CAEF-7BAD-4594-A537-4CC9E4BA16D6", "versionEndExcluding": "3.1", "versionStartIncluding": "3.0"}, {"criteria": "cpe:2.3:a:beckhoff:twincat:2.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "4C156F0C-E0B7-42C3-9A0B-64264D0C42DE"}, {"criteria": "cpe:2.3:a:beckhoff:twincat:3.1:build_4022:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A30C25C0-DF20-4F75-B054-04CB69E4828B"}, {"criteria": "cpe:2.3:a:beckhoff:twincat:3.1:build_4024.0:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C2C4531C-B547-4E56-AD4C-E6D65BEFEE02"}], "operator": "OR"}]}], "sourceIdentifier": "cve@mitre.org"}