Show plain JSON{"id": "CVE-2018-7301", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 7.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2018-02-22T19:29:06.547", "references": [{"url": "http://atomic111.github.io/article/homematic-ccu2-xml-rpc", "tags": ["Third Party Advisory"], "source": "cve@mitre.org"}, {"url": "http://atomic111.github.io/article/homematic-ccu2-xml-rpc", "tags": ["Third Party Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-306"}]}], "descriptions": [{"lang": "en", "value": "eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices."}, {"lang": "es", "value": "Los dispositivos eQ-3 AG HomeMatic CCU2 2.29.22 tienen un puerto XML-RPC abierto sin autenticaci\u00f3n. Esto puede aprovecharse mediante el env\u00edo de peticiones XML-RPC arbitrarias para controlar los dispositivos BidCos conectados."}], "lastModified": "2024-11-21T04:11:58.033", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:eq-3:homematic_central_control_unit_ccu2_firmware:2.29.22:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "51B22E1E-E0C8-46DA-9BE7-3D915B0B056C"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:eq-3:homematic_central_control_unit_ccu2:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "250E0A8B-A3F3-4A65-9C9D-8327EB1D99E5"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cve@mitre.org"}