Show plain JSON{"id": "CVE-2018-7243", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 10.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "authentication": "NONE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": true, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2018-04-18T20:29:00.420", "references": [{"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-074-01/", "tags": ["Vendor Advisory"], "source": "cybersecurity@se.com"}, {"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-074-01/", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "NVD-CWE-noinfo"}]}], "descriptions": [{"lang": "en", "value": "An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to get a full access to device, bypassing the authorization system."}, {"lang": "es", "value": "Existe una vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n en 66074 MGE Network Management Card Transverse, de Schneider Electric, instalados en MGE UPS y MGE STS. El servidor web integrado (Port 80/443/TCP) de los dispositivos afectados podr\u00eda permitir que un atacante remoto obtenga acceso completo al dispositivo omitiendo el sistema de autorizaci\u00f3n."}], "lastModified": "2024-11-21T04:11:51.923", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:66074_mge_network_management_card_transverse:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7DBB8697-64F8-4D15-8B14-CDD51E99FBCF"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:mge_comet_ups:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F9837318-C9B6-448E-B701-40929C96795A"}, {"criteria": "cpe:2.3:h:schneider-electric:mge_eps_6000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "98078458-B5AB-4AD2-9E57-390591469F37"}, {"criteria": "cpe:2.3:h:schneider-electric:mge_eps_7000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "05DE2424-0969-491D-A414-81A648F2F801"}, {"criteria": "cpe:2.3:h:schneider-electric:mge_eps_8000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "60DC5EF0-1929-4D67-89BF-47D6F6848411"}, {"criteria": "cpe:2.3:h:schneider-electric:mge_galaxy_3000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "955C94DD-90E6-4AB1-87CC-4EDACEA47DF0"}, {"criteria": "cpe:2.3:h:schneider-electric:mge_galaxy_4000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "7FCAE877-B3E9-4970-B0EE-49C64C85715C"}, {"criteria": "cpe:2.3:h:schneider-electric:mge_galaxy_5000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "4EBFA4F2-6574-4D58-9B0C-317229DF503E"}, {"criteria": "cpe:2.3:h:schneider-electric:mge_galaxy_6000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "790BF7D0-4E2D-4607-8C47-C4B707538E66"}, {"criteria": "cpe:2.3:h:schneider-electric:mge_galaxy_9000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "54A1FC87-5319-4F69-9228-C664D505B1CC"}, {"criteria": "cpe:2.3:h:schneider-electric:mge_galaxy_pw:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "59D9633E-051F-427A-BADA-61BC8501AAE9"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cybersecurity@se.com"}