Show plain JSON{"id": "CVE-2018-7239", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 6.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "MEDIUM", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 7.8, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.8}]}, "published": "2018-03-09T23:29:00.967", "references": [{"url": "http://www.securityfocus.com/bid/103338", "tags": ["Third Party Advisory", "VDB Entry"], "source": "cybersecurity@se.com"}, {"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02", "tags": ["Third Party Advisory", "US Government Resource"], "source": "cybersecurity@se.com"}, {"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/", "tags": ["Vendor Advisory"], "source": "cybersecurity@se.com"}, {"url": "http://www.securityfocus.com/bid/103338", "tags": ["Third Party Advisory", "VDB Entry"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02", "tags": ["Third Party Advisory", "US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-426"}]}], "descriptions": [{"lang": "en", "value": "A DLL hijacking vulnerability exists in Schneider Electric's SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code."}, {"lang": "es", "value": "Existe una vulnerabilidad de secuestro de DLL en SoMove Software de Schneider Electric y en los componentes de software DTM asociados, en todas las versiones anteriores a la 2.6.2. Esto podr\u00eda permitir que un atacante ejecute c\u00f3digo arbitrario."}], "lastModified": "2024-11-21T04:11:51.273", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:atv_lift_dtm:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8F0F8212-5CC6-4EB7-9F37-4587FC849A54", "versionEndExcluding": "12.7.0"}, {"criteria": "cpe:2.3:a:schneider-electric:atv12_dtm:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "70DDF782-E80B-41A6-88F0-52D3BCCD0BE6", "versionEndExcluding": "12.7.0"}, {"criteria": "cpe:2.3:a:schneider-electric:atv212_dtm:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8A9E382F-DBB4-4B24-81C7-EE33B5248935", "versionEndExcluding": "12.7.0"}, {"criteria": "cpe:2.3:a:schneider-electric:atv31_dtm:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2429408E-48C9-4F97-A918-4DDECF6A7AB2", "versionEndExcluding": "12.7.0"}, {"criteria": "cpe:2.3:a:schneider-electric:atv312_dtm:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "44D79762-E0D3-4DB9-8DD8-AE6A93953411", "versionEndExcluding": "12.7.0"}, {"criteria": "cpe:2.3:a:schneider-electric:atv32_dtm:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "DC70CB2D-2AA8-40EC-97BC-0527D5F100ED", "versionEndExcluding": "12.7.0"}, {"criteria": "cpe:2.3:a:schneider-electric:atv320_dtm:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1D1862C8-5571-4DAC-B9F0-96DC3F2F846F", "versionEndExcluding": "1.1.6"}, {"criteria": "cpe:2.3:a:schneider-electric:atv340_dtm:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CB77B51C-CA0B-4C6E-91D2-41C450C6214E", "versionEndExcluding": "1.2.3"}, {"criteria": "cpe:2.3:a:schneider-electric:atv600_dtm:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FE8C39E7-A682-4453-945F-D1DFC9418A7C", "versionEndExcluding": "1.8.0"}, {"criteria": "cpe:2.3:a:schneider-electric:atv61_dtm:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "988EB546-BB63-4DEF-800E-5C5A3C796163", "versionEndExcluding": "12.7.0"}, {"criteria": "cpe:2.3:a:schneider-electric:atv71_dtm:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "848353C2-B49E-4B88-A57A-C783BF47C84C", "versionEndExcluding": "12.7.0"}, {"criteria": "cpe:2.3:a:schneider-electric:atv900_dtm:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "3BA8B718-4947-41FE-9DDC-DA3AB85992B3", "versionEndExcluding": "1.3.5"}, {"criteria": "cpe:2.3:a:schneider-electric:somove:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "AD8AD349-3536-4244-8D10-D860A5A7F1FF", "versionEndExcluding": "2.6.2"}], "operator": "OR"}]}], "sourceIdentifier": "cybersecurity@se.com"}