Show plain JSON{"id": "CVE-2018-13114", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 7.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2018-10-22T20:29:00.287", "references": [{"url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html", "tags": ["Exploit", "Third Party Advisory"], "source": "cve@mitre.org"}, {"url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html", "tags": ["Exploit", "Third Party Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-306"}]}], "descriptions": [{"lang": "en", "value": "Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the \"ssid\" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command."}, {"lang": "es", "value": "Falta de autenticaci\u00f3n y validaci\u00f3n de entradas incorrecta en KERUI Wifi Endoscope Camera (YPC99) permite que un atacante ejecute comandos arbitrarios (con un l\u00edmite de longitud de 19 caracteres) mediante el valor \"ssid\", tal y como queda demostrado con ssid:;ping 192.168.1.2 en el cuerpo de un comando SETSSID."}], "lastModified": "2024-11-21T03:46:28.017", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:keruigroup:ypc99_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A648BF89-A0F2-41C9-BFED-3A7CC6618E93"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:keruigroup:ypc99:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "5CCDD63D-DB5C-49A3-BAF3-362E09CCAE80"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cve@mitre.org"}