Show plain JSON{"id": "CVE-2017-9944", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 10.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "authentication": "NONE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": false, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": true, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2017-12-27T17:08:25.000", "references": [{"url": "http://www.securityfocus.com/bid/101184", "tags": ["Third Party Advisory", "VDB Entry"], "source": "productcert@siemens.com"}, {"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-971654.pdf", "tags": ["Vendor Advisory"], "source": "productcert@siemens.com"}, {"url": "http://www.securityfocus.com/bid/101184", "tags": ["Third Party Advisory", "VDB Entry"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-971654.pdf", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Deferred", "weaknesses": [{"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-288"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-269"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in Siemens 7KT PAC1200 data manager (7KT1260) in all versions < V2.03. The integrated web server (port 80/tcp) of the affected devices could allow an unauthenticated remote attacker to perform administrative operations over the network."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en el gestor de datos (7KT1260) 7KT PAC1200 de Siemens, en todas las versiones anteriores a la V2.03. El servidor web integrado (puerto 80/tcp) de los dispositivos afectados podr\u00eda permitir que un atacante remoto no autenticado realice operaciones administrativas a trav\u00e9s de la red."}], "lastModified": "2025-04-20T01:37:25.860", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:7kt_pac1200_data_manager_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C248B6B6-0C07-40ED-882B-CC07F3FC03C1", "versionEndExcluding": "2.03"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:7kt_pac1200_data_manager:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "069F6E95-B8DD-4727-B89E-613A8BBF21B9"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "productcert@siemens.com"}