Show plain JSON{"id": "CVE-2015-8561", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 6.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "MEDIUM", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true}]}, "published": "2015-12-15T05:59:09.797", "references": [{"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01", "tags": ["Vendor Advisory"], "source": "cve@mitre.org"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-626", "source": "cve@mitre.org"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-627", "source": "cve@mitre.org"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-628", "source": "cve@mitre.org"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-629", "source": "cve@mitre.org"}, {"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02", "tags": ["Third Party Advisory", "US Government Resource"], "source": "cve@mitre.org"}, {"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-626", "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-627", "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-628", "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-629", "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02", "tags": ["Third Party Advisory", "US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Deferred", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-119"}]}], "descriptions": [{"lang": "en", "value": "The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918."}, {"lang": "es", "value": "El control F1BookView ActiveX en F1 Bookview in Schneider Electric ProClima en versiones anteriores a 6.2 permite atacantes remotos ejecutar c\u00f3digo arbitrario o causar una denegaci\u00f3n de servicio (corrupci\u00f3n de memoria) a trav\u00e9s de un valor entero manipulado con el m\u00e9todo (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx o (5) SwapTable, una vulnerabilidad diferente a CVE-2015-7918."}], "lastModified": "2025-04-12T10:46:40.837", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "12DFD1A6-BDB8-4864-A3E3-1CBF1609C17B", "versionEndIncluding": "6.1"}], "operator": "OR"}]}], "sourceIdentifier": "cve@mitre.org"}