Show plain JSON{"id": "CVE-2013-2823", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 4.7, "accessVector": "LOCAL", "vectorString": "AV:L/AC:M/Au:N/C:N/I:N/A:C", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "MEDIUM", "availabilityImpact": "COMPLETE", "confidentialityImpact": "NONE"}, "acInsufInfo": false, "impactScore": 6.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 3.4, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}]}, "published": "2013-11-22T01:55:03.917", "references": [{"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-01", "tags": ["US Government Resource"], "source": "ics-cert@hq.dhs.gov"}, {"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-02", "tags": ["US Government Resource"], "source": "ics-cert@hq.dhs.gov"}, {"url": "http://support.ge-ip.com/support/index?page=kbchannel&id=S:KB15805", "tags": ["Vendor Advisory"], "source": "ics-cert@hq.dhs.gov"}, {"url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15805/en_US/GEIP13-04%20Security%20Advisory%20-%20Proficy%20HMI%20SCADA%20DNP3%20Driver%20from%20Catapult%20Software.pdf", "tags": ["Vendor Advisory"], "source": "ics-cert@hq.dhs.gov"}, {"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-01", "tags": ["US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-02", "tags": ["US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "http://support.ge-ip.com/support/index?page=kbchannel&id=S:KB15805", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15805/en_US/GEIP13-04%20Security%20Advisory%20-%20Proficy%20HMI%20SCADA%20DNP3%20Driver%20from%20Catapult%20Software.pdf", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Deferred", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-20"}]}], "descriptions": [{"lang": "en", "value": "The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line."}, {"lang": "es", "value": "El driver (1) Catapult DNP3 I/O anterior a la versi\u00f3n 7.2.0.60 y el driver (2) GE Intelligent Platforms Proficy DNP3 I/O anterior a la versi\u00f3n 7.20k, tal y como se usa en DNPDrv.exe (tambi\u00e9n conocido como servidor de estaci\u00f3n maestro DNP) en GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY y iFIX, permite f\u00edsicamente a atacantes pr\u00f3ximos provocar una denegaci\u00f3n de servicio (bucle infinito) a trav\u00e9s de una entrada manipulada sobre una linea de serie."}], "lastModified": "2025-04-11T00:51:21.963", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:catapultsoftware:catapult_dnp3_i\\/o_driver:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0D4D11DB-CF90-4ADD-AB95-9815FC90F97B", "versionEndIncluding": "7.20.56"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:*:j:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9FBAD16C-05F0-4D83-8FE7-F3FD0E2B75C7", "versionEndIncluding": "7.20"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "92C2AB50-34CB-4296-8CCE-B98026DB4F0E"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:a:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "4BE9590D-9264-4942-A18C-8629420FBB24"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:b:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A013ED7F-92C1-42C4-A6AB-4A419BA11611"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:c:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FA7AE477-C0A4-497E-8F7B-9D656DC41B2F"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:d:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C8AECEB6-867F-4796-B56C-C3C8BC53D691"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:e:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9ABC3786-A578-4BF3-AF3D-A470BD7565CB"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:f:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "142CA198-EF41-4FFD-BB40-F9B41C4841F2"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:g:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F058E97B-0B63-4059-968D-9D282570283B"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:h:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "ED4490C3-8CE5-4715-8E19-1793ED16354D"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:i:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "91B378AA-1AFA-44D7-8403-C898C3DAE85D"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:4.01:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6C0B8CA7-2161-4603-B844-DE6C079DF36F"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:7.5:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E3BACB11-5CD3-4CA6-9C56-D71628CADF0F"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "90538C50-38BD-4EE5-BD30-96E2E2951FE3"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.1:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CB261867-B9B1-4D3D-B2DE-3CC3164EFD06"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.2:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "559DCD7A-0745-4D4C-A77A-83240EF6C510"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_ifix:5.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "65A4CBC3-3B98-4700-8710-4D4FFCA55315"}, {"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_ifix:5.1:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "5ABA340B-B00B-41EC-8270-68139B63D09A"}], "operator": "OR"}]}], "sourceIdentifier": "ics-cert@hq.dhs.gov"}